  1. Make 'auto enforce DRC' respect the layers that a via features on

    The 'auto enforce DRC' feature currently behaves as if vias pass
    through all layers of the PCB.  This patch makes this feature check
    the layers that a via passes through.
    
    For example, if a via passes through layers 1-3 and we are routing a
    trace on layer 4, then the current implementation prohibits a trace
    from being routed on layer 4 through the same coordinates as the via.
    With this patch the routing is permitted.
    
    Signed-off-by: bert <bert.timmerman@xs4all.nl>
    rgilton authored and bert committed May 27, 2025